Fbu (Force Backup) - Comtech EF Data DT-4572 Installation And Operation Manual

X-band down converter
Hide thumbs Also See for DT-4572:
Table of Contents

Advertisement

DT-4572 X-Band Down Converter
Serial Interface Operation
Description
Switching Mode:
Confirmation:
Automatic Status:
Confirmation:
8.7.4.4

FBU (Force Backup)

Use FBU to force a backup condition for maintenance and test purposes. This
command is only accepted by the backup converter (i.e., "BU"). When activated,
this command forces the chain converter offline, and forces the backup
converter to assume the state of the specified chain converter.
Description
Force a Backup:
Confirmation:
Return Backup Status:
Confirmation:
Details
<DEV/SAM_xx_y{cr}
>DEV/SAM_xx_y{cr}{lf}]
<DEV/SAM_xx_{cr}
>DEV/SAM_xx_y{cr}{lf}] where:
xx = converter number 01 to 12
y = A for Auto; M for Manual
Details
<DEV/FBU_xx_y{cr}
>DEV/FBU_xx_y{cr}{lf}] where:
xx = converter number 01 to 12
y = 'F' to force a backup, 'N' to remove a backup
<DEV/FBU_{cr}
>DEV/FBU_xx_zzzzz{cr}{lf}] where:
xx = converter number 01 to 12
zzzzz = 'NONE' if no backup active (converter number is not displayed);
'ACTIVE' if an automatic backup has occurred;
'FORCED' if a forced backup is active
8–26
MN/DT4572.IOM
Revision 1

Advertisement

Table of Contents
loading

Table of Contents