DT-4572 X-Band Down Converter
Firmware Update
5.4.4.2 Reboot the Unit
5.4.4.2.1 Hard-reboot the Unit from the Rear Panel
Typical for either the standard AC unit or the optional DC unit:
1. From the unit rear panel, switch the power OFF, and then turn the power
back ON.
2. Verify the new firmware version has booted; for example, check the
firmware version displayed on the DT-4572 front panel:
SW VER X.X.X
5.4.4.2.2 Soft-reboot the Unit from the HTTP Interface
Do these steps from the HTTP Interface 'Config | Utility' page:
1. In the 'Perform Soft Reboot' section, click [Reboot Now]:
2. Wait while the DT-4572 reboots with the Current Active Firmware Image.
3. To load a second image, repeat the tasks described throughout Section
5.4.4.
The DT-4572 is now operating with its latest firmware. The firmware update
process is complete.
DT_4572
SN#########
5–15
MN/DT4572.IOM
Revision 1
Need help?
Do you have a question about the DT-4572 and is the answer not in the manual?
Questions and answers