Genie Z-45/25 Service And Repair Manual page 42

Ic power
Table of Contents

Advertisement

Service and Repair Manual
Platform Controls
9
Select a boom function joystick to set the
threshold.
10 Slowly move the joystick off center in either
direction just until the function begins to move.
11 Slowly move the joystick back towards the
neutral position. Just before the function stops
moving, move the drive enable toggle switch
to either side to set the threshold.
Result: The alarm should sound indicating a
successful calibration.
Note: For each joystick axis, the threshold must be
set for both directions.
12 Repeat steps 9 through 11 for each direction
of boom joystick controlled machine function
(boom up/down, boom extend/retract and
turntable rotate left/right).
13 Return the joystick to the neutral position and
wait for approximately 10 seconds to allow the
settings to be saved.
Result: The alarm should sound indicating that
the settings have been saved in memory.
Note: Do not operate any machine function during
the 10 second waiting time.
14 Cycle the red Emergency Stop button off, then
back on.
28
Z-45/25 • Z-45/25J
September 2016
Part No. 1268548