SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP Description
4766
0
1029 Physical range check high for
exhaust gas temperature
downstream (DOC)
4766
1
1032 Physical range check low for
exhaust gas temperature
downstream (DOC)
4768
2
1036 Sensor exhaust gas temperature
upstream (DOC); plausibility
error
4768
3
1044 Sensor error exhaust gas
temperature upstream (DOC);
signal range check high
4768
4
1045 Sensor error exhaust gas
temperature upstream (DOC)
signal range check low
4769
2
1026 Sensor exhaust gas temperature
downstream (DOC); plausibility
error
4769
3
1034 Sensor error exhaust gas
temperature downstream (DOC);
signal range check high
4769
4
1035 Sensor error exhaust gas
temperature downstream (DOC);
signal range check low
523006
3
34
Controller mode switch; short
circuit to battery
523006
4
35
Controller mode switch; short
circuit to ground
523008
1
648
Manipulation control was
triggered
523008
2
649
Timeout error in Manipulation
control
523009
9
825
Pressure Relief Valve (PRV)
reached maximun allowed
opening count
523009
10
833
Pressure relief valve (PRV)
reached maximun allowed open
time
Part No. 1268548
Deutz D 2.9 L4 Engine Fault Codes
SPN
FMI KWP Description
523212
9
523216
9
523240
9
523350
4
523352
4
523354
12
523470
2
523470
2
523470
7
523470
11
523470
11
523470
12
523470
12
523470
14
523550
12
523601
13
523603
9
Z-45/25 • Z-45/25J
Service and Repair Manual
171
Timeout Error of
CAN-Receive-Frame
ComEngPrt; Engine Protection
198
Timeout Error of
CAN-Receive-Frame
PrHtEnCmd; pre-heat command,
engine command
179
Timeout CAN-message
FunModCtl; Function Mode
Control
565
Injector cylinder-bank 1; short
circuit
566
Injector cylinder-bank 2; short
circuit
567
Injector powerstage output defect
826
Pressure Relief Valve (PRV)
forced to open; performed by
pressure increase
827
Pressure Relief Valve (PRV)
forced to open; performed by
pressure shock
876
Maximum rail pressure in limp
home mode exceeded (PRV)
831
The PRV can not be opened at
this operating point with a
pressure shock
832
Rail pressure out of tolerance
range
828
Open Pressure Relief Valve
(PRV); shut off condition
829
Open Pressure Relief Valve
(PRV); warning condition
830
Pressure Relief Valve (PRV) is
open
980
T50 start switch active for too
long
948
Sensor supply voltage monitor
3 error (ECU)
126
Timeout Error of
CAN-Receive-Frame AMB;
Ambient Temperature Sensor