Monitoring > Errors > Transmitted (Tx) - D-Link DSG-1100-10/ME Manual

Table of Contents

Advertisement

D-Link DGS-1100-10/ME User Manual
Figure 4.125 - Monitoring > Errors > Received (RX) (table)
The following fields can be set or viewed:
Time Interval: Select the desired setting between 1s and 60s, where "s" stands for seconds. The default
value is one second.
Record Number: Select the number of times the Switch will be polled between 20 and 200. The default
value is 200.
CRC Align: Counts otherwise valid packets that did not end on a byte (octet) boundary.
UnderSize: The number of packets detected that are less that the minimum permitted packets size of 64
bytes and have a good CRC. Undersize packets usually indicate collision fragments, a normal network
occurrence.
OverSize: Counts packets received that were longer that 1518 octets, or if a VLAN frame is 1522 octets, and
less that the MAX_PKT_LEN. Internally, MAX_PKT_LEN is equal to 1522.
Fragment: The number of packets less than 64 bytes with either bad framing or an invalid CRC. These are
normally the result of collisions.
Jabber: The number of packets with lengths more than the MAX_PKT_LEN bytes. Internally,
MAX_PKT_LEN is equal to 1522.
Show/Hide: Check whether or not to display CRC Error, Under Size, Over Size, Fragment, Jabber, and
Drop errors.
Clear: Click to clear all statistic counters on this window.
View Table: Click to display a table rather than a line graph.
View Line Chart: Click to display a line graph rather than a table.
Monitoring > Errors > Transmitted (TX)
This page displays the following graph of error packets transmitted on the Switch. To select a port to view
these statistics for, select the port by using the Port drop-down menu. You may also use the real-time
graphic of the Switch at the top of the web page by simply clicking on a port.
7
7
6
6