4.8.8

Default setting of the interfaces

Default setting 1: "Conveyor technology with 2 fixed frequencies"
DO 0: p0730, DO 1: p0731
Fixed speed setpoint 3: p1003, fixed speed setpoint 4: p1004, fixed speed setpoint active: r1024
Speed setpoint (main setpoint): p1070[0] = 1024
DI 4 and DI 5 = high: the inverter adds the two fixed speed setpoints
Designation in the BOP-2: coN 2 SP
Default setting 2: "Conveyor system with Basic Safety"
DO 0: p0730, DO 1: p0731
Fixed speed setpoint 1: p1001, fixed speed setpoint 2: p1002, fixed speed setpoint active: r1024
Speed setpoint (main setpoint): p1070[0] = 1024
DI 0 and DI 1 = high: the inverter adds the two fixed speed setpoints.
Designation in the BOP-2: coN SAFE
SINAMICS G120C converter
Operating Instructions, 07/2015, FW V4.7 SP3, A5E34263257B AC
AO 0: p0771[0]
AO 0: p0771[0]
Installing
4.8 Connecting the inverter
DI 0: r0722.0, ..., DI 5: r0722.5
DI 0: r0722.0, ..., DI 5: r0722.5
71