Anti-Tip Bracket Installation - Amana rs2310004-aro3100 Service

Manual clean gas ranges
Table of Contents

Advertisement

Installation Instructions Open Burner
Converting Type 1 Pressure Regulator for Use with
Natural Gas
1. Remove pressure regulator cap with a wrench.
2. Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.
3. Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Insert must show "NAT" or be blank.
4. Place pressure regulator cap on pressure regulator
and tighten.
• Insert should not disturb spring in body of
regulator.
Converting Type 2 Pressure Regulator for Use with
Natural Gas
1. Remove pressure regulator cap with a wrench.
2. Reverse pressure regulator cap.
• Insert shows "NAT" or is blank.
3. Place pressure regulator cap on pressure regulator
and tighten.
Converting Surface Burners for Use with
Natural Gas
1. Lift the rangetop off of the range.
2. Turn all 4 orifice hoods (loosen) clockwise when
facing front of range 1½ to 2 turns.
• Use ½-inch crescent wrench.
3. Close all 4 air shutters to approximately
Converting Oven Burner for Use with Natural Gas
1. Remove broiler drawer.
2. Turn orifice hood counterclockwise (loosen) 2 full
turns.
3. Close air shutter to approximately
4. Replace broiler door.
Converting Oven Thermostat for Use with Natural
Gas
1. Remove 4 burner control knobs from range.
• Exposes 2 screws on burner control panel.
2. Remove 2 screws from burner control panel.
• Panel drops slightly after screws are removed.
3. Grasp bottom of burner control panel, gently lift and
pull out panel until clear of burner valve stems.
• After burner control panel clears valve stems,
continue to roll panel until free from range. Set
aside.
4. Turn the selector screw so the pointer is towards "N".
5. Reverse steps 1-3 to replace control panel and
knobs.

Anti-tip Bracket Installation

To reduce risk of range tipping, secure range with a
properly installed anti-tip bracket.
1. Measure 3
2. Position anti-tip bracket.
1
/
inch.
8
3
/
inch.
8
3. Mark 2 hole locations in anti-tip bracket.
4. Drill 2 holes.
5. Secure bracket to floor using screws supplied.
6. After range is slide into position, verify the range
15
1
/
inches from back wall on right and left
2
side of cabinet cutout. Mark measurements on floor
and draw a straight line connecting marks.
• If range is installed beside cabinet(s), place anti-
tip bracket with back edge on line drawn on floor
and side of bracket against cabinet.
• If range is not installed beside cabinet(s), position
range where it will be installed. Draw a line along
side of range on floor from front to back. Remove
range. Place anti-tip bracket with back edge over
line drawn 3
1
/
inches from back wall and side of
2
bracket over line drawn along side of range on
floor.
• Anti-tip bracket can be installed on either right or
left side.
or
• If drilling into wood, use a
• If drilling into concrete, use a
drill bit and insert plastic anchors.
leveling leg has engaged anti-tip bracket.
3 1/2"
3
/
inch drill bit.
32
3
/
inch masonry
16
RS2310004 Rev. 1

Advertisement

Table of Contents
loading