DK14 Installation
Site Requirements
Input Power
The system requires an input power source of 115VAC ± 10VAC, 50/60 Hz, 10 amps. The AC
outlet is recommended to be dedicated and unswitched, with a solid third-wire ground. (See
Power and Grounding Requirements" on Page 1-3
This is to eliminate interference from branch circuit motor noise or the like, and to prevent
accidental power-off. To avoid accidental power turn-off, Toshiba recommends that you do not use
an On/Off wall switch on this dedicated AC circuit.
For the DK14, a reserve power source (two customer-supplied 12-volt batteries) may be connected
to the system to serve as a power failure backup.
Clearance and Location
The minimum clearance requirements for the DK14
KSU are shown in
mounted directly above the D14 KSU.
Consider the following conditions when selecting a
location for the KSU(s):
The location must be:
o
Dry and clean
o
Well ventilated
o
Well illuminated
o
Easily accessible
The location must not be:
Subject to extreme heat or cold
o
o
Subject to corrosive fumes, dust, or other
airborne contaminants
Subject to excessive vibration
o
o
Next to television, radio, office automation, or
high frequency equipment
1-2
Figure
1-1. The HPFB should be
for details).
Front View
HPFB
DK14 KSU
2"
10"
Top View
Figure 1-1
DK14 KSU Clearance
Requirements
"AC
2"
2"
16.4"
2"
2"
3"
Wall
3' Front Clearance
2399
Strata DK I&M
6/00