Smdr Programming - Toshiba STRATA DK14 Installation And Maintenance Manual

Hide thumbs Also See for STRATA DK14:
Table of Contents

Advertisement

Peripheral Installation
SMDR Printer/Call Accounting Device Options
o
o
Notes
If the CO provides the Calling Party Control or Auto Release (AR) signal (see Program 15-0
G
and 15-3), the call disconnects when either party hangs up. A "*" will follow the CO line
number in Release 1 and 2 and precede the CO line number in Release 3 on the printout if the
call is disconnected by the CPC or AR signal.
If the CPC or AR signal is not sent, the CO lines will remain seized until the DISA disconnect
G
timer releases the call (see Program 12).
Printout C
Auto Release signal: (Release 1 and 2)
003 MSS 12:20 00:00;02 00:06 (outgoing)
003* DISA 12:22 00:02;01 (outgoing)
001 DISA 12:22 00:02;01 (incoming)
Auto Release signal (Release 3 and above)
003 MSS 12:20 00:00;03 00:05 DISA (outgoing)
*003 DISA 12:22 00:02;01 (outgoing)
001 DISA 12:22 00:02;01 (incoming)
Disconnect Timer (Release 1 and 2)
001 DISA 12:24 00:04;57 (incoming)
003 DISA 12:24 00:04;57 (outgoing)
Disconnect Timer (Release 3 and above)
001 DISA 12:24 00:04;57 (incoming)
003 DISA 12:24 00:04;57 (outgoing)
Note

SMDR Programming

Program 03
o
The SMDR output is provided by the PIOU or PIOUS with the lowest code assigned (41, 42,
or 43).
o
If using RSIU or RSIS PCB (DK424) in slot 11 for SMDR, set Program 03 code 49 for slot 11.
Notes
WSIU (DK14) and TSIU (DK40i) do not require a Program 03 slot assignment.
G
RSIU/RSIS (DK424) Program 76-1 code x2 overrides PIOU/PIOUS SMDR assignments and
G
code 49 for RSIU/RSIS.
12-38
Caller hangs up.
The call releases, and Printout C prints after the call disconnects at 12:22.
The "MSS" entry prints out only if the call was connected after the SMDR threshold, 1.0
or 10 seconds. The threshold is set in Program 60-2.
Strata DK I&M
6/00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk 424iDk 14Dk 424Dk40iDk 424i