Pdiu-Ds To Printer Installation - Toshiba STRATA DK14 Installation And Maintenance Manual

Hide thumbs Also See for STRATA DK14:
Table of Contents

Advertisement

o
LED 05: Should be On if the system is installed behind a PBX or Centrex that uses access
codes to make external calls or to insert a pause following RPCI DIU access of an outside
line.
o
LED 10: Enables Caller ID and ANI information to be sent from RCPI-DI to the
connected PC.
LED 11: Enables DNIS information to be sent from the RCPI-DI to the connected PC.
o
LEDs 17~20: Used to establish data security groups. RPCI and PDIU stations are only
o
allowed to make calls to RPCI and PDIUs in the same assigned data group.
o
Program 39: The following data call buttons can be assigned digital telephones equipped with
'DWD &DOO
PDIU-DIs:
'66
assign
buttons to data devices;

PDIU-DS to Printer Installation

Strata DK enables serial printers (laser, dot matrix, or other types) to be connected to stand-alone
data interface units (PDIU-DSs). Digital telephones equipped with RPCI or PDIU-DIs can share
access to these printers. Serial printers operate as DCE or DTE devices, depending on the vendor;
the PDIU-DS can be connected to either type, since it can be configured as a DTE or DCE device.
(The PDIU-DS comes from the factory configured as a DCE device.)
➤ To connect the PDIU-DS to a serial printer
Notes
Only serial printers (not parallel) that conform to EIA RS-232 signaling requirements can be
G
connected to PDIU-DSs.
In rare applications, it may be desired to connect printers to PDIU-DIs. See the printer's
G
installation instructions.
1. Consult the serial printer's documentation and determine if the printer operates as a DCE or
DTE device. Also, see
If the printer is a DCE device: Disassemble the PDIU-DS and configure it to operate like a
DTE device by placing the jumper plugs (P1~P9) in the "B-C" (MODEM) position.
Reassemble the PDIU-DS, and mark "B-C" on the bottom label for future reference.
If the printer is a DTE device: You may not need to disassemble the PDIU-DS, since it comes
factory-direct configured as a DCE device. However, if uncertain, disassemble the PDIU-DS
and verify that jumper plugs (P1~P9) are in the "A-B" (DTE) position. Reassemble the PDIU-
DS and mark "A-B" on the bottom label for future reference.
2. Connect the PDIU-DS to the appropriate digital telephone circuit per wiring diagrams in
Chapter 10 – Universal Slot PCB Wiring and Chapter 11 – Station Apparatus.
3. Connect the appropriate RS-232 cable between the printer and the PDIU-DS (see
12-27
and
12-29
4. If Steps 2 and 3 are done properly, the Power and Ready LEDs on the PDIU-DS light when the
printer is turned on and ready.
5. Set the PDIU-DS DIP switch (SW1-1~4) for the application. See
locations.
Note
If using Toshiba computers and printers with X-On/X-Off flow control, set SW1-(4) "On"
on the DIU connected to the computer and DIU connected to the printer.
Strata DK I&M
6/00
0RGHP
, and
. Assign
'66
buttons are used for voice calls only.
Figures 12-31
and 12-33.
for an example printer cable connection).
PC/Data Communications Interface Units
6'
buttons to data devices as required. Do not
Figure 12-32
Peripheral Installation
Figures
for DIP switch
12-61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk 424iDk 14Dk 424Dk40iDk 424i

Table of Contents