To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Convection Relay

When the convection element is selected by the oven
control board, voltage is sent to the convection relay
coils. A red LED in front of each coil verifies coil voltage
is being sent to that particular relay. This does not
indicate however that the relay is functioning. When the
convection element relay is energized, (L1-black) power
is sent through the relay to the convection element. (L2
power is controlled by the line break relay.)
To test, select a Convection cooking program. When
the convection relay contact is energized (red LED lit at
base of relay), check for 240 VAC between the yellow
wire at the line break relay and the white/red wire on
P2. If 0 VAC is read, disconnect power and remove P2
Molex plug.
Reconnect power and using your ohmeter, check for
continuity between the two relay contacts (refer to photo,
above). If you read infinite ohms (∞) when the relay is
energized, this indicates a faulty relay and you will need
to replace the control board. If you read 0 ohms, the
relay contact is closing.

Cooling Fan

Locate the P11 terminal connections on the control
board. The P11 connections will have Molex plug
containing two white/black wires.
With the P11 board connection removed, use an
ohmeter to measure resistance between either white/
black wire and P1 white wire on the power supply board.
The resistance should be approximately 18 ohms. If no
resistance is read, remove fan to repair/replace (Follow
the cooling fan disassembly procedure).
©2012 Viking Preferred Service
With the white/black wires attached to the P11 board
connection, use a voltmeter to measure voltage between
the white/black wires on the board and P1 white on the
power supply board. The voltage should be 120 VAC
when a cooking mode is selected. If 120 VAC is present
and no fan rotation, replace the cooling fan (follow
cooling fan disassembly procedure). If no voltage is
present, verify wiring. If wiring is OK, replace the oven
control board.

Cooling Fan Relay

The oven control board is designed to operate a two-
speed cooling motor. The oven utilizes a one-speed
motor so both the HI and LO speeds are jumped
together on the board. On initial startup, the oven control
board selects the fan power relay (K8) and the LO speed
(K9). When the oven temp reaches 250˚F temp, the
board will switch the speed relay to HI. However, both
are jumped together so this change is not noticed. If a
fan error is shown, proceed with the test shown below.
When the unit is switched ON, voltage is sent to both
relay coils. A red LED in front of each coil verifies coil
voltage is being sent to that particular relay. This does
not indicate however that the relays are functioning.
To test, connect power. With your meter set for AC
voltage, check between P1 white on power supply board
and the white/black wires on P11 (refer to photo above).
The reading should be 120 VAC. If 0 volts are shown
and the red LED is lit, then the oven control board is
defective.
Troubleshooting
13