Omron Smart Process Control CJ-Series Brochure & Specs page 3

Fully integrated sequence and loop control new built-in loop controller
Table of Contents

Advertisement

Function blocks make loop-control programming easy. You can also create
CX-Process Tool tuning windows to help adjust loops. Controller faceplates
can be created automatically for touch panel displays.
Sequence control programs: Standardize and simplify programs using structured programming. Special I/O
Unit and CPU Bus Unit settings are easy with function blocks (using ladder programming language or
structured text).
Loop control programs: By combining function blocks, a wide array of control methods can be easily
configured, from basic PID control used by Temperature Controllers to program, cascade, and feed-forward
control. Easily display values, such as temperatures, in engineering units, allowing you to check operation.
Engineering Example: Program Control
Loop-control CPU Unit
CX-Process Tool (Software for Personal Computer)
Combine function blocks and connect graphically
SP
1
using the mouse.
Analog Input
Field Terminal
Y1
Time
Y2
Y3
Y4
RSP
PV
TIC
MV
Segment
Program
Analog
Analog
Y1
Input
Output
Unit
Unit
Input
Output
channel 1
channel 1
Temperature
Heater output
input
Lineup includes low-cost models that use up to 50 function
blocks and models that allow up to 300 blocks designed for
large-scale systems and complicated operations.
Loop control: Programming with function blocks to suit the application.
System configuration: Choose and combine functions from a broad selection of I/O Units.
Perform
Read data from
Perform PID
heating/cooling
Analog Input
control
control
Units
Analog Input
Basic PID
Split Conversion
Field Terminal
Y1
PV
SP
X1
Y2
DV
Y3
RSP
MV
Y4
Y5
Y6
Y7
Y8
Set point (SP)
Segment
Program 2
X1
Y1
Y2
Perform program
control
T0
T1 T2
T3
T4
4
Face Plate Auto-Builder for NS
Touch panel windows are automatically generated.
3
NT-series PT
Analog Output
Basic PID
Field Terminal
PV
X1
X2
RSP
MV
X3
X4
Serial or
Ethernet
communications
Adjust PID and other parameters
2
in the tuning window.
Loop-control CPU Unit
System Configuration
Control output
from Analog
Output Unit
Analog Output
Field Terminal
Y1
X1
10 Units max.
Expansion Rack
Y2
X2
X3
X4
X5
X6
10 Units max.
X7
Expansion Rack
X8
10 Units max.
Expansion Rack
10 Units max.
Note: CJ1G-CPU44P/45P
T5
T6
T97 T98 T99 T100
TIME
(CJ1G-CPU42P/43P: Expand up to 2 Racks)
Control window
Tuning window
Segment program
parameter setting window
New Algorithm Further Enhances Control
Process Input
Stability
Units, Analog
I/O Units, etc.
Disturbance Overshoot Adjustment
This function restrains overshoot when a disturbance is
generated, allowing faster stabilization.
[Example]
• Temperature drops when adding objects to a furnace
• Control disturbances when retooling
Optimum Tuning to Suit the Application
Expansion
Rack: 3
Fine Tuning
Racks
max.
Adjust PVs, SPs, and MVs while monitoring, and save
(See note.)
data as CSV files from the software tuning window.
Autotuning (AT) and fine-tuning functions can also be
used for automatically calculating PID constants (see note
2).
Note 1: For details on CS-series Loop Control Boards, refer to the PLC-based
Process Control Catalog (Cat. No. P051).
2: Control can be fine-tuned by automatically tuning PID parameters using
previous control parameters and three user-set requirements to execute
fuzzy logic.
Simply turn the DIP Switch ON/OFF to save or read the
user program including function blocks using the
Memory Card.
Simple backup function enables backup, recovery, and comparison of all PLC data including the
function block programs for the Loop Control Board using the Memory Card.
Save tag settings, comments, annotations, and connection data created using the CX-Process
Tool to either a Memory Card or a Loop-control CPU Unit.
Press the
Memory Card
power supply
switch for 3 s.
Consolidating OMRON's expertise in temperature and process control
cultivated over many years to provide you with effortless solutions
using proven algorithms.
Loop control: Proven functionality of Temperature Controllers and CS-series Loop Control
Boards (see note 1) in a compact size.
Disturbance generated
Disturbance
CS-Process Tool Tuning Window
Note: Supported by unit version 3.0 or later.
CPU Unit
Function
block
program
Sequence
program
Memory
I/O memory
Card
Simple backup
to Memory
Parameter Area
Card, including
function block
data.
Condition: Pin 7 is ON
Conventional PID gain adjustment
Longer time required
to stabilize
Overshoot
Using the Disturbance
Time required to
Overshoot Adjustment function
stabilize
Faster stabilization
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1g-cpu**pSysmac cj series

Table of Contents