Cpu Bus Units - Omron Smart Process Control CJ-Series Brochure & Specs

Fully integrated sequence and loop control new built-in loop controller
Table of Contents

Advertisement

Ordering Information

CPU Bus Units

■ Controller Link Units
Controller Link Units, New Models
Unit
Product
classifi-
name
cation
Communica-
tions cable
CJ1
Control-
Wired shielded
CPU
ler Link
twisted-pair cable
Bus
Unit
(See note 2.)
Unit
Controller Link Units, Old Models
New models are fully compatible with old models and provide enhanced functionality, such as an increase in the number of send words from
1,000 to 4,000 words. Select a new model when ordering.
Unit
Product
classifi-
name
cation
Communica-
tions cable
CJ1
Controller
Wired shielded
CPU
Link Unit
twisted-pair cable
Bus
(See note 2.)
Unit
Note: Use the following special cable for shielded, twisted-pair cable.
• ESVC0.5 x 2C-13262 (Bando Electric Wire: Japanese Company)
• ESNC0.5 x 2C-99-087B (Nihon Electric Wire & Cable Corporation: Japanese Company)
2
• ESPC 1P x 0.5 mm
(Nagaoka Electric Wire Co., Ltd: Japanese Company)
• Li2Y-FCY2 x 0.56qmm (Kromberg & Schubert, Komtec Department: German Company)
• 1 x 2 x AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)
• #9207 (Belden: US Company)
Repeater Units
Unit classification
Controller Link
Wire-to-wire Model
Repeater Unit
Wire-to-Optical (H-PCF) Model (See note 2.)
Wire-to-Optical (GI) Model (See note 3.)
Note: 1. Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks. 62-node configurations, and con-
verting part of the network to optical cable.
2. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable
with connector.
3. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).
Relay Terminal Block
Unit classification
Relay Terminal Block
Use for Wired Controller Link Units (set of 5).
for Wired Controller
Link Unit
Note: Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in
advance on the Unit in a Wired Controller Link network. Relay Blocks cannot be used on Controller Link Support Boards.
32
Specifications
Communi-
Duplex
Max. Units
cations
support
mountable
type
per CPU
Unit
Data links
No
8
and mes-
sage service
Specifications
Communi-
Duplex
Max. Units
cations
support
mountable
type
per CPU
Unit
Data links
No
8
and mes-
sage service
Specifications
Specifications
No. of unit
Current con-
numbers
sumption (A)
allocated
5 V
24 V
1
0.35
---
CJ1W-CLK23
No. of unit
Current con-
numbers
sumption (A)
allocated
5 V
24 V
1
0.35
---
CJ1W-CLK21-V1
Model
CS1W-RPT01
CS1W-RPT02
CS1W-RPT03
Model
CS1W-TB101
CPU Bus Units
Model
Standards
UC1, N, L,
CE
Model
Standards
UC1, N, L,
CE
Standards
UC1, CE
Standards
---

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1g-cpu**pSysmac cj series

Table of Contents