Software Specifications - Omron Smart Process Control CJ-Series Brochure & Specs

Fully integrated sequence and loop control new built-in loop controller
Table of Contents

Advertisement

CX-Process Tool and Monitor
CX-Process Tool and Monitor

Software Specifications

Item
Name
Model number
Applicable PLCs
Applicable Units
Compatible com-
Computer
puters
CPU
OS
Memory
Hard disk storage
Monitor
CD-ROM drive
Sound board
Mouse
Communications
Connection with CPU Unit
method
(or Serial Communica-
tions Board/Unit)
Connection via Controller
Link
Connection via Ethernet
14
CX-Process Tool
CX-Process
WS02-LCTC1-EV5
CS-series PLCs
CJ-series PLCs
CJ-series Loop-control CPU Units
CS-series Loop Control Units/Boards
CS1D Process-control CPU Units
IBM PC/AT or compatible
Intel CPU (Core, Pentium, or Celeron family)
For Windows Vista: 1 GHz min.
For any other OS: 333 MHz min. required, 1 GHz min. recommended
Microsoft Windows 2000 (Service Pack 3 or higher), NT4.0
(Service Pack 6a), 98SE, Me (See note 1), XP, or Vista (Ul-
timate or Business)
For Windows Vista, 1 GB min.
For any other OS: 256 MB min. required, 512 MB min. rec-
ommended
Min. required: 350 Mbytes of free space,
Recommended: 450 Mbytes or more of free space (includ-
ing approx. 280 Mbytes used by communications middle-
ware)
Minimum: XGA
Recommended: SXGA 65,536 colors or more
1 drive min.
---
Recommended: Microsoft mouse or compatible pointing device
When FinsGateway Serial Unit driver is used:
Communications protocol with PLC: Host Link or Peripheral Bus (See note 2.)
• Connect the computer to the peripheral port or built-in RS-232C port of the CPU Unit, or to the
RS-232C port of the Serial Communications Board/Unit.
• Connecting cable:
For connecting to peripheral port of CPU Unit: CS1W-CN@@@ (2 m or 6 m)
For connecting to RS-232C port of CPU Unit: XW2Z-@@@-@ (2 m or 5 m)
When CX-Server is used:
Communications protocol with PLC: Host Link or Peripher-
al Bus
Connecting Cable:
• For connecting to peripheral port of CPU Unit:
CS1W-CN@@@ (2 m or 6 m)
For connecting to RS-232C port of CPU Unit:
XW2Z-@@@-@ (2 m or 5 m)
When FinsGateway Controller Link driver or CX-Server is used:
Install the software in a computer with a Controller Link Support Board to communicate with a PLC with a
Controller Link Unit mounted.
When FinsGateway ETN_UNIT driver or CX-Server is used:
Install the software in a computer with an Ethernet Board to communicate with a PLC with an Ethernet Unit
mounted.
Software Specifications
Specifications
CX-Process Monitor Plus
CX-Process Monitor Plus
WS02-LCMC1-EV2
CJ-series Loop-control CPU Units
CS-series Loop Control Units/Boards
CS1D Process-control CPU Units
Microsoft Windows 2000, NT4.0, or XP
Minimum:
96 Mbytes
Recommended: 128 Mbytes min.
Minimum:
650 Mbytes free space
(Including approximately 50 Mbytes used for
communications middleware and other purpos-
es)
Minimum requirement: XGA
(XGA or above recommended)
1
CX-Server is not supported.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1g-cpu**pSysmac cj series

Table of Contents