Loop-Control Cpu Units - Omron Smart Process Control CJ-Series Brochure & Specs

Fully integrated sequence and loop control new built-in loop controller
Table of Contents

Advertisement

Loop-control CPU Units

Loop-control CPU Units
Loop-control CPU Units
Model
I/O capacity
CJ1G-CPU45P
1,280 points
(Up to 3 Expansion
CJ1G-CPU45P-
Racks)
GTC
CJ1G-CPU44P
CJ1G-CPU43P
960 points (Up to 2
Expansion Racks)
CJ1G-CPU42P
Loop Controller Element Specifications
Item
Name
Model Number
Applicable PLCs
Area for data
CPU Unit's
exchange
Auxiliary Area
with CPU Unit
User allocations in
I/O Memory
Allocations for all
data
Settings
Indicators
Super capacitor backup data
Super capacitor backup time
Data stored in flash memory
Backup from RAM to flash memory Executed from CX-Process Tool (as required).
Recovery from flash memory to
RAM
Influence on CPU Unit cycle time
Current consumption (supplied
from Power Supply Unit)
10
CPU Unit element
Program
Data memory capacity
capacity
60 Ksteps
128 K words (DM: 32 K words,
EM: 32 K words × 3 banks)
30 Ksteps
64 K words (DM: 32 K words,
EM: 32 K words × 1 bank)
20 Ksteps
10 Ksteps
Loop-control CPU Unit
CJ1G-CPU@@P(-GTC)
CJ-series PLCs
• Loop Controller element-to-CPU Unit element:
Run Status Flag, PV Error Input Flag, MV Error Input Flag, Execution Error Flag, Function Block Data-
base (RAM) Error Flag, Automatic Cold Start Execution Flag, Backup during Operation Flag, Function
Block Changed Flag, etc.
• CPU Unit element-to-Loop Controller element:
Start Mode at Power ON: Hot/Cold Start bit.
User link tables are used to allocate function block ITEM data in any part of I/O memory in the CPU Unit.
(CIO, Work, Holding, or DM Areas, or EM Area bank 0)
HMI function used to allocate function block ITEM data for Control, Operation, External Controller, and
System Common blocks in the specified bank of the EM Area in the CPU Unit.
None
Two LED indicators: RUN and ready
All function block data (including sequence tables, step ladder program commands), stored error log data
5 minutes at 25 ° C
Function block data
Automatically transferred when power to CPU Unit is turned ON if startup mode is set for a cold start, or
executed from CX-Process Tool (as required).
0.8 ms max. (depends on function block data contents)
1.06 A for 5 VDC (current consumption for Loop-control CPU Unit including CPU Unit element and Loop
Controller element)
Note: Increased by 150 mA when NT-AL001 Link Adapter is used.
Loop-control CPU Units
Programming
Number of
software
function blocks
CX-Programmer,
300 blocks
CX-Simulator, etc.
50 blocks
Specification
Loop Controller
Programming
software
CX-Process

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1g-cpu**pSysmac cj series