Error Codes - Panasonic AJ-SPX800P Operating Instructions Manual

Hide thumbs Also See for AJ-SPX800P:
Table of Contents

Advertisement

9. Battery Nearly Empty
Display window
One of the bars in the battery remaining indicator
indication
starts blinking.
WARNING lamp
Blinks once per second.
Tally lamp
Blinks once per second.
Viewfinder
The BATT LED blinks.
Warning tone
Beeps 4 times per second.
Warning
The battery is about to run out.
description
Recording/
Continues to operate.
playback operation
Countermeasures
Replace the battery as required.
10. P2 Card Nearly Full
Display window
One of the bars for remaining MEDIA capacity
indication
starts blinking.
Blinks
WARNING lamp
continues.
Blinks
Tally lamp
continues.
Viewfinder
The P2 card remaining capacity indicator blinks.
Beeps
Warning tone
continues.
Warning
The total remaining capacity of all the P2 cards is
description
two minutes or less.
Recording/
Continues to operate.
playback operation
Replace the cards. If there is an empty card slot,
Countermeasures
insert a new card.
Downloaded From VideoCamera-Manual.com Manuals
once
per
second
while
recording
once
per
second
while
recording
once
per
second
while
recording

7-3-2 Error Codes

The following error codes are displayed in the display window if
an error occurs in the camera:
Code No.
E-11
Video initialisation error
E-27
Recording control error
E-30
P2 card removal error
E-38
P2 streaming microcontroller error
E-3F
Microprocessor error in the camera control circuit.
E-6F
Reference signal error.
Description