IBM x3650 M3 Installation And User Manual page 22

Types 4255, 7945, and 7949
Hide thumbs Also See for x3650 M3:
Table of Contents

Advertisement

Table 1. Features and specifications (continued)
Electrical input with hot-swap ac power
supplies:
v Sine-wave input (47 - 63 Hz) required
v Input voltage range automatically
selected
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA)
approximately:
– Minimum: 0.090 kVA
– Maximum: 0.700 kVA
EU Regulation 617/2013 Technical Documentation:
Product Type:
Year first manufactured:
Internal/external power supply efficiency:
8
System x3650 M3 Types 4255, 7945, and 7949: Installation and User's Guide
Environment:
v Air temperature:
– Server on: 10°C to 35°C (50.0°F to
95.0°F); altitude: 0 to 914.4 m (3000
ft). Decrease system temperature by
1°C for every 1000-foot increase in
altitude.
– Server off: 5°C to 45°C (41.0°F to
113.0°F); maximum altitude: 3048 m
(10000 ft)
– Shipment: -40°C to +60°C (-40°F to
140°F); maximum altitude: 3048 m
(10000 ft)
v Humidity:
– Server on: 20% to 80%; maximum
dew point: 21°C; maximum rate of
change 5°C per hour.
– Server off: 8% to 80%; maximum
dew point: 27°C
– Shipment: 5% to 100%
v Particulate contamination:
Attention: Airborne particulates and
reactive gases acting alone or in
combination with other environmental
factors such as humidity or
temperature might pose a risk to the
server. For information about the limits
for particulates and gases, see
"Particulate contamination" on page
183.
International Business Machines Corporation
New Orchard Road
Armonk, New York 10504
http://www.ibm.com/customersupport/
For more information on the energy efficiency program, go to
http://www.ibm.com/systems/x/hardware/energy-star/index.html
Computer Server
2010
PSU 1: Go to http://www.plugloadsolutions.com/psu_reports/
IBM_7001578-XXXX_675W_SO-485_Report.pdf
PSU 2:
Table 2. Power supply efficiency (PSU 2)
IRMS A
PF
0.41
0.811
0.72
0.901
1.65
0.956
ITHD (%)
Load (%)
39.8%
10%
30.5%
20%
21.8%
50%
Hot-swap fans: Three - provide redundant
cooling.
Power supply:
v Up to two hot-swap power supplies for
redundancy support
– 460-watt ac
– 675-watt ac
– 675-watt high-efficiency ac
– 675-watt dc
Note: You cannot mix 460-watt and
675-watt power supplies, or high-efficiency
and non-high-efficiency power supplies, or
ac and dc power supplies in the server.
Acoustical noise emissions:
v Declared sound power, idle: 6.3 bel
v Declared sound power, operating: 6.5 bel
Heat output:Approximate heat output:
v Minimum configuration: 662 Btu per
hour (194 watts)
v Maximum configuration: 2302 Btu per
hour (675 watts)
Input
Output
Watts
Watts
77.25
67.50
148.45
134.74
361.99
336.34
Efficiency
%
87.38%
90.76%
92.91%

Hide quick links:

Advertisement

Table of Contents
loading