Power Trim Does Not Operate (Motor Does Not Operate); Power Trim Does Not Operate (Motor Operates But Sterndrive Unit Does Not Move) - MerCruiser Axius 350 MAG User Manual

Hide thumbs Also See for Axius 350 MAG:
Table of Contents

Advertisement

Section 7 - Troubleshooting
The steering wheel turned past
end stop.

Power Trim Does Not Operate (Motor Does Not Operate)

Blown fuse.
Loose or dirty electrical connections or damaged
wiring.

Power Trim Does Not Operate (Motor Operates but Sterndrive Unit Does Not Move)

Trim pump oil level low.
Drive unit binding in gimbal ring.
Page 136
Symptom
Key off and key on to restore steering wheel self‑centering, cruise control,
and to eliminate the fault code.
Possible Cause
Possible Cause
Remedy
Remedy
Replace fuse. Fuses may be located near the dash
trim switch, at the trim pump, in the positive (red)
power trim battery lead near the battery switch, or a
combination of these.
Check all associated electrical connections and wires
(especially battery cables). Clean and tighten faulty
connection. Repair or replace wiring.
Remedy
Fill pump with oil.
Check for obstruction.
90-899883234 JANUARY 2008