Three-Point Manual Drain System; Boat In The Water - MerCruiser Axius 350 MAG User Manual

Hide thumbs Also See for Axius 350 MAG:
Table of Contents

Advertisement

Section 6 - Storage
3. Visually verify that water is draining. If water does not drain, remove the blue drain plug
from the distribution housing and drain manually.
4. Allow the system to drain for a minimum of five minutes. We recommend leaving the
plugs out while transporting the boat or performing other maintenance to ensure that
all water is drained.
5. Close the drain system by rotating the blue handle clockwise until it stops or installing
the blue drain plug. The handle is fully seated when no red is visible. Do not overtighten
handle, as this action will create new threads.
Three‑Point Manual Drain System

BOAT IN THE WATER

NOTE: Use this procedure if your engine is not equipped with an air‑actuated single‑point
drain system or if the air‑actuated single point drain system fails.
1. Close the seacock (if equipped) or remove and plug the water inlet hose.
2. Remove the blue drain plug from the distribution housing (lower front, port side).
Page 124
b
a
a -
Drain location ‑ orange or red
a -
Blue drain plug
6137
b -
Blue drain plug
a
6138
90-899883234 JANUARY 2008