Nameplate And Decals Assy - MULTIQUIP TLG8SSK4F Operation And Parts Manual

Portable generator
Table of Contents

Advertisement

3
OPERATING PROCEDURE
MULTIQUIP WhisperWatt
Before connecting this generator to any building's
AC Generator
electrical system, a licensed electrician must install
1. Check the oil level.
an isolation [transfer] switch.
2. Check the water level.
9.
Let the engine idle for more than 5 minutes
with the Idle Control switch in"ON" position.
3. Check the fuel level.
10.
4. Turn the Idle Control switch to "ON."
Check the engine for abnormal vibrations noise
and oil leakage.
5. Insert the key into the Starter Switch.
11. Turn the Idle Control switch to either "ON"or
Serious injury or death may result without this
6. Turn the key to"RUN". The Charge
"OFF" for full engine operation.
Warning lamp and the Oil Pressure Warning lamp
12. After generating let the engine run for 5 minutes
transfer switch.
should be lit.
with the Idle Control switch in the"ON" position.
7. Turn the key to "HEAT." When the preheat lamp
NEVER STOP THE ENGINE SUDDENLY EXCEPT
lights turn the key to"START" t o start the engine.
IN AN EMERGENCY.
AVOID HIGH SPEEDS IMMEDIATELY AFTER
13. Stop the engine by turning the key in the
STARTING.
Starter Switch to"STOP" and remove the key.
8. When the engine starts, the Oil Pressure
Alarm lamp should go out.
A555000103
F
15
WARNING
To avoid injury,
you MUST read
and understand
37
operator's manual
E
before using this
machine.
This machine to
be operated by
qualified
personnel onl y .
Ask for trainin g
as needed.
P/N 35137
DANGER
34
Using a generator indoors CAN KILL YOU IN MINUTES
Generator exhaust contains carbon monoxide. This is
a posion you cannot see or smell
2900
20 A
12 0
GA-2.9 R
V
2900
20 A
12 0
2900
20 A
12 0
120V
AC CIRCUI
BREAKE
R
T
GA-2.9 R
120V
BREAKER
AC CIRCUI
T
V
GA-2.9 R
120V
T
BREAKE
AC CIRCUI
R
V
ON
OF F
OF F
ON
ON
OF F
Only use OUTSIDE and
NEVER use inside a home
far away from windows,
or garage, even if doors
doors, and vents.
and windows are open
Avoid other generator hazards.
READ MANUAL L BEFORE USE
.
DANGER
THE POSSIBILITY EXISTS OF
ELECTROCUTION
GENERATOR/WELDER IS NOT PROPERLY GROUNDED.
ALWAYS CONNECT EARTH GROUND (GROUND
ROD) TO GENERATOR G.F.C.I. GROUND TERMINAL.
33
GROUND
CABLE
G E
G R
N E
#8 MINIMUM
O U
R AT
N D
O R
LU
G.F.C.I
G
GROUND
STUD
FOR FURTHER GROUNDING
INSTRUCTIONS, READ MANUAL
8 FT. MINIMUM
REFERENCE
NEC 250-52(C)
32
COOLING
24
PAGE 62 — TLG8SSK4F PORTABLE GENERATOR• OPERATION AND PARTS MANUAL — REV. #0 06/21/16)
5
4
WARNING!
CAUTION
CHECK DAILY
1. Radiator water level.
2. Reserve tank water level.
(Important) Not more than
WATER
a 50/50 Anti-Freeze/Water
COOLANT
mixture is recommended.
LEVEL
3. Engine oil level.
H
RESERVE
L
TANK
WHIS PERW ATT
F
7.5kV A AC GEN
ERAT OR
F
1/ON
E
PS
JET
20
50 A
AC220V 25kA
QUARTZ
AC CIRCUIT BREAKER
AC CIRCUIT BREAKER
FOR 3-PHASE OUTPUT
G. F. C. I. PROTECT
ED
E
36
IF
GROUND ROUND
FOR EARTH
GROUND
CONNECT TO
BUILDING
GROUND
(OPTION)
D93110000
FRONT VIEW
WARNING
HOT COOLANT can cause
severe burns.
DO NOT remove cap if
radiator is hot.
DCL183
WATER
S-3061
17

NAMEPLATE AND DECALS ASSY.

26
30
FUSE PULLY
F6
F5
15A
WARNING
F4
5A
DIESEL FUEL
can cause
fire or explosion.
F3
5A
.
Stop engine before fueling.
.
DCL194
F2
5A
Keep cigarettes, sparks
and flame away.
F1
30A
RUN
HIGH
STOP
VOLTAG E REGUL
ATOR
LOW
STARTER SWITCH
DECREAS E
ENGINE SPEED
INCREASE
SWITCH
1
DA NG ER
Do not touch
internal wiring
output terminals
while unit is
or
Turn off power
operating .
S-4985
before servicing.
ELECTR IC
Only qualified
SHOCK
personne l should
HAZARD
install, use or
equipmen t.
service this
35
6
GROUND
USE #2 DIESEL
14
USE ULTRA LOW SULFUR
FUEL ONLY
S-1408
17
19
18
16
29
WARNING
25
MOVING PARTS can cause
severe injury.
DO NOT operate with
doors open.
Stop engine before
servicing.
DCL182
22
B90450000
20
2
CAUTION:
DO NOT
OPERATE WITH
DOORS OPEN
CAUTION
Before starting the engine, check that the oil
level is within the indicated operating range.
If the level is above the
the
L
mark
, it is important to correct before
operating to avoid damage to the engine.
COOLANT DRAIN
OIL DRAIN
CAUTION
CLEAN OR
REPLACE
PAPER ELEMENT
EVERY 100 HOURS
FUEL COCK
OFF
ON
DANGER
Cigarettes, flames or sparks could cause battery to explode. Always
shield eyes and face from battery. Do not charge or use booster cables
or adjust post connections without proper instruction and training.
KEEP VENT CAPS TIGHT AND LEVEL
POISON
Contains sulfuric acid. Avoid contact with skin, eyes or clothing. In
FUEL DRAIN
event of accident flush with water and call a physician immediately.
KEEP OUT OF REACH OF CHILDREN
S-3060
13
23
S-1123
WARNING
Only operate machine in well ventilated
7
areas.
DO NOT inhale exhaust gases.
S-4984
Only qualified personnel should
DANGEROUS
install, use or service this
GAS
equipment.
MOVING PARTS can cause
severe injury.
DO NOT operate with
doors open.
Stop engine before
servicing.
21
S-4985
ELECTRIC
SHOCK
HAZARD
2
SIDE VIEW
S-1409
25
OIL LEVEL
DIPSTICK
H
H
mark
or below
L
12
S-1404
11
S-1403
28
S-1406
27
EXPLOSIVE GASES
10
CAUSES SEVERE BURNS
8
S-2090
9
S-2091
WARNING
29
DCL182
CAUTION
HOT PARTS
can burn skin.
31
DO NOT
touch until the
machine has sufficiently
cooled.
DCL181
DANGER
6
Do not touch output terminals or
internal wiring while unit is operating.
Turn off power before servicing.
Only qualified personnel should
install, use or service this
equipment.

Advertisement

Table of Contents
loading

Table of Contents