4. If the engine does not start within 10 seconds after the
key is turned to the START position, wait for about 30
seconds and repeat the procedure as described in
steps 1-3.
5. When the engine starts, the oil pressure light and
charge light should go out. If these lights stay on,
immediately stop the engine and check the system and
wiring (refer to the Engine Operation Manual).
6. Let the engine idle for five minutes with the Engine
Speed Switch (Figure 25) placed in the LOW position.
Figure 25. Engine Speed Switch (LOW)
Output Voltage Verification
1. Place Engine Speed Switch circuit breaker (Figure
26) in the HIGH position.
Figure 26. Engine Speed Switch (HIGH)
2. The generator's frequency meter (Figure 27) should
be displaying the 60 cycle output frequency in HERTZ.
Figure 27. Frequency Meter
PAGE 30 — TLG8SSK4F PORTABLE GENERATOR• OPERATION AND PARTS MANUAL — REV. #0 06/21/16)
LOW
HIGH
3. The generator's AC voltmeter (Figure 28) will display
the generator's output in VOLTS.
Figure 28. Voltmeter
4. Use the voltage adjustment control knob to increase
or decrease voltage (Figure 29).
Figure 29. Voltage Adjust Control Knob
5. The ammeter (Figure 30) will indicate zero amps with
no load applied. When a load is applied, the ammeter
will indicate the amount of current that the load is
drawing from the generator.
Figure 30. Ammeter (No Load)
6. Place 3-phase and 1-phase circuit breakers (Figure 31)
in the ON position.
e
F
ON
PS
JET
E
50 A
AC220V 25kA
AC CIRCUIT BREAKER
FOR 3-PHASE OUTPUT
Figure 31. 3-Phase and 1-Phase Circuit
Breakers (ON)