5 Fuser unit error
•
Do fuser errors occur right after power ON?
(A)
•
Yes Is the heat roller thermister disconnected or generating a short circuit? (See Fig. 5-1)
(Approx. 190k-980kΩ in room temperature of 0-43 degrees Celsius.)
•
Yes Replace the fuser unit.
•
No
Is the back-up roller thermister disconnected or generating a short circuit? (See Fig. 5-1)
(Approx. 190k-980kΩ in room temperature of 0-43 degrees Celsius.)
•
Yes Replace the fuser unit.
•
No
•
No
Does a fuser unit error occur approx. three minutes after power ON?
•
No
Proceed to (A).
•
Is the heater in the fuser unit turned ON? (Is it hot?)
•
Yes Replace the engine board.
•
No
Replace the fuser unit.
•
No
Is AC voltage output between CN1 connector pin 1 and pin 3 in the low-voltage power unit?
•
No
Replace the low-voltage power unit.
•
Yes
Replace the fuser unit.
41956001TH Rev.6
Heat roller thermister
Figure 5.1
Oki Data CONFIDENTIAL
Back-up roller thermister
120 /