A
Paper thickness error (Err Code 323, 324)
•
Is the sensor connector connected?
NO
Connect the connecter.
•
YES
Is the sensor cable disconnected?
NO
Replace the cable.
•
YES
Is +5V output to the PU board REG 13pin?
NO
Replace the PU board.
•
YES
IS GND connection made to the PU board REG 15pin?
NO
Replace the PU board.
•
YES
Is pulse signal 5ms ON 10% Duty output to the PU board REG 16pin?
(Disabled on field due to sync usage.)
NO
Replace the PU board.
•
YES
Turn ON the power and check the media thickness. Is the error released?
NO
Replace the sensor.
•
YES: End.
41956001TH Rev.6
Oki Data CONFIDENTIAL
135 /