Outdoor Unit
2.8
Removal of
Procedure
Step
1. Remove the parts around
the compressor.
1
Remove the terminal
cover and the lead
wires of the
compressor so as not
to be burnt out by a gas
brazing machine.
146
Compressor
Warning Be sure to turn off all power supplies at least 10 min. before disassembling work.
Procedure
Si06-305
Points
Be careful so as not to burn
the compressor terminals or
the name plate.