Specifications

1.
Specifications
1.1

Cooling Only

Indoor Units
Model
Outdoor Units
Capacity
Rated (Min.~Max.)
Moisture Removal
Running Current (Rated)
Power Consumption Rated
(Min.~Max.)
Power Factor (Min.~Max.)
COP
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Indoor Unit
Front Panel Color
Air Flow Rate m³/min
(cfm)
Type
Motor Output
Fan
Upper/Lower
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (W×D×H)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power H
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant
Oil
Charge
Model
Refrigerant
Charge
m³/min (H/L)
Air Flow Rate
cfm (H/L)
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (W×D×H)
Weight
Gross Weight
Operation
H/L
Sound
Sound Power H
Drawing No.
Notes:
4
kW
Btu/h
8,550 (3,400~10,250)
kcal/h
2,150 (860~2,580)
L/h
A
W
%
W/W
mm
mm
mm
Both Liquid and Gas Pipes
H
M
L
SL
W
Steps
5 Steps, Silent and Auto
Right, Left, Horizontal and Upward
Removable / Washable / Mildew Proof
A
W
%
Microcomputer Control
mm
mm
kg
kg
dBA
dBA
Hermetically Sealed Swing Type
W
L
kg
W
A
W
%
A
mm
mm
kg
kg
dBA
dBA
MAX. interunit piping length: 25m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
FVKS25BVMB
RKS25BVMB
2.5 (1.0~3.0)
1.2
3.7
700 (240~925)
82.3
3.57
φ
6.4
φ
9.5
φ
20.0
FVKS25BVMB
Almond White
8.1 (286)
6.2 (219)
4.3 (152)
3.4 (120)
Cross Flow Fan
14/14
0.14
32
99.4
600×650×195
770×294×714
13
19
38 / 32 / 26 / 23
54
RKS25BVMB
Ivory White
1YC23GXD#A
600
FVC50K
0.4
R410A
0.96
25.3/17.0
893/600
Propeller
19
3.56
668
81.6
3.7
560×695×265
797×310×599
37
40
46 / 43
59
3D040164A
Piping Length
7.5m
230V, 50Hz
FVKS35BVMB
RKS35BVMB
3.5 (1.0~3.7)
11,950 (3,400~12,600)
3,010 (860~3,180)
1.9
5.5
1,160 (240~1,300)
91.7
3.02
φ
6.4
φ
9.5
φ
20.0
Both Liquid and Gas Pipes
FVKS35BVMB
Almond White
8.3 (293)
6.3 (222)
4.3 (152)
3.4 (120)
Cross Flow Fan
14/14
5 Steps, Silent and Auto
Right, Left, Horizontal and Upward
Removable / Washable / Mildew Proof
0.14
32
99.4
Microcomputer Control
600×650×195
770×294×714
13
19
39 / 33 / 27 / 24
55
RKS35BVMB
Ivory White
Hermetically Sealed Swing Type
1YC23GXD#A
600
FVC50K
0.4
R410A
1.06
25.3/17.0
893/600
Propeller
19
5.36
1,128
94.0
5.5
560×695×265
797×310×599
37
40
47 / 44
60
3D040165A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications
Si06-305

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rks35bvmbFvks35bvmbRks25bvmb