Si06-305
1.2

Heat Pump

Indoor Units
Model
Outdoor Units
Capacity
Rated (Min.~Max.)
Moisture Removal
Running Current (Rated)
Power Consumption Rated
(Min.~Max.)
Power Factor (Min.~Max.)
COP
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Indoor Unit
Front Panel Color
Air Flow Rate m³/min
(cfm)
Type
Motor Output
Fan
Upper/Lower
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (W×D×H)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power H
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant
Oil
Charge
Model
Refrigerant
Charge
m³/min (H/L)
Air Flow Rate
cfm (H/L)
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (W×D×H)
Weight
Gross Weight
Operation
H/L
Sound
Sound Power H
Drawing No.
Notes:
Specifications
Cooling
kW
2.5 (1.0~3.0)
Btu/h
8,550 (3,400~10,250)
kcal/h
2,150 (860~2,580)
L/h
1.2
A
3.7
W
700 (240~925)
%
82.3
W/W
3.57
mm
mm
mm
Both Liquid and Gas Pipes
H
8.1 (286)
M
6.2 (219)
L
4.3 (152)
SL
3.4 (120)
W
Steps
5 Steps, Silent and Auto
Right, Left, Horizontal and Upward
Removable / Washable / Mildew Proof
A
0.14
W
32
%
99.4
Microcomputer Control
mm
mm
kg
kg
dBA
38 / 32 / 26 / 23
dBA
54
Hermetically Sealed Swing Type
W
L
kg
25.3/17.0
893/600
W
A
3.56
W
668
%
81.6
A
mm
mm
kg
kg
dBA
46 / 43
dBA
59
MAX. interunit piping length: 20m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
FVXS25BVMB
RXS25BVMB
Heating
3.4 (1.0~5.0)
11,600 (3,400~17,050)
2,920 (860~4,300)
4.3
840 (240~1,430)
84.9
4.05
φ
6.4
φ
9.5
φ
20.0
FVXS25BVMB
Almond White
9.2 (325)
7.0 (247)
4.8 (169)
3.5 (124)
Cross Flow Fan
14/14
0.14
32
99.4
600×650×195
770×294×714
13
19
38 / 32 / 26 / 23
RXS25BVMB
Ivory White
1YC23GXD#A
600
FVC50K
0.4
R410A
0.96
22.8/15.3
805/540
Propeller
19
4.16
808
84.4
4.3
560×695×265
797×310×599
37
40
47 / 44
3D040172A
Heating
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
Specifications
FVXS35BVMB
RXS35BVMB
Cooling
3.5 (1.0~3.7)
4.5 (1.0~5.0)
11,950 (3,400~12,600)
15,350 (3,400~17,050)
3,010 (860~3,180)
3,870 (860~4,300)
1.9
5.5
1,160 (240~1,300)
1,285 (240~1,830)
91.7
3.02
φ
6.4
φ
9.5
φ
20.0
Both Liquid and Gas Pipes
FVXS35BVMB
Almond White
8.3 (293)
6.3 (222)
4.3 (152)
3.4 (120)
Cross Flow Fan
14/14
5 Steps, Silent and Auto
Right, Left, Horizontal and Upward
Removable / Washable / Mildew Proof
0.14
32
99.4
Microcomputer Control
600×650×195
770×294×714
13
19
39 / 33 / 27 / 24
39 / 34 / 29 / 26
55
RXS35BVMB
Ivory White
Hermetically Sealed Swing Type
1YC23GXD#A
600
FVC50K
0.4
R410A
1.06
25.3/17.0
893/600
Propeller
19
5.36
1,128
91.5
6.0
560×695×265
797×310×599
37
40
47 / 44
60
3D040173A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Piping Length
7.5m
230V, 50Hz
Heating
6.0
93.1
3.50
9.2 (325)
7.1 (251)
5.0 (177)
3.6 (127)
0.14
32
99.4
22.8/15.3
805/540
5.86
1,253
93.0
48 / 45
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rks35bvmbFvks35bvmbRks25bvmb

Table of Contents