Installation Checklist; Locating Your Outdoor Decorative Gas Appliance - Regency Plateau PTO30-NG1 Owners & Installation Manual

Hide thumbs Also See for Plateau PTO30-NG1:
Table of Contents

Advertisement

INSTALLATION
CHECKLIST
1) Locate appliance:
a) Refer to "Locating Your Outdoor decorative
gas appliance" section
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
2) Drain Installation (recommended).
3) Install ON/OFF switch - ensure it is in the OFF
position.
4) Make gas connections - test for leaks.
5) Install 4 "AA" batteries into each battery pack.
This unit will not operate without AA batteries
in place.
6) Install standard and optional features. Refer to
the following sections:
a.
Tabletop Installation
b.
Glass Crystals
c.
Volcanic Stone Installation (optional)
d.
Glass Surround Installation
e.
Weather Cover Installation
7) Final check.
This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label), after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in dam-
age is not the responsibility of the manufacturer.
WARNING: DO NOT BUILD FRAME FOR
HOUSING CYLINDER UNLESS COMPLI-
ANCE TO AS 4565 AND AS/NZS 5601.1 ARE
ASSURED.
THIS APPLIANCE MUST BE INSTALLED TO A
PERMANENTLY CONNECTED NATURAL GAS
PIPING SYSTEM, OR A PERMANENTLY CON-
NECTED PIPING SYSTEM TO A REMOTE LPG
SUPPLY TANK
Regency Plateau™ PTO30 Outdoor Gas Fireplace
OUTDOOR DECORATIVE GAS APPLIANCE
PTO30 BURNER MUST BE INSTALLED AT A MINIMUM OF 750MM ABOVE GROUND. IF IN-
STALLED LOWER, IT IS REQUIRED TO INSTALL THE DECORATIVE GLASS SURROUND AND
ENSURE MINIMUM HEIGHT IS 750MM TO TOP OF GLASS SURROUND.
IF INSTALLED LOWER THAN 750MM WITH GLASS SURROUND, INSTALLER MUST PROVIDE
A MEANS OF SECONDARY GUARD, NOT ATTACHED TO, BUT SURROUNDING THE PTO30
BURNER WITH A MINIMUM HEIGHT OF 750MM.
1) When selecting a location for your decorative gas appliance, ensure that the clearances are met.
2) This appliance must be installed in an open-air situation with natural ventilation, without stagnant
areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural
convection.
3) Certain materials or items, when placed under or near the appliance, will be subjected to radiant
heat and could become damaged.
4) Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall
comply with one of the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and no
overhead cover.
Within a partial enclosure that includes an overhead cover and no more that two walls.
Within a partial enclosure that includes an overhead cover and more than two walls, the following
shall apply:
At least 25% of the total wall area is completely open, and
At least 30% of the remaining wall area is open and unrestricted
30% or more in total of the remaining wall
area is open and unrestricted.
In the case of balconies, at least 20% of
the total wall area shall be and remain
open and unrestricted.
LOCATING YOUR
Open side at least 25% of total wall area
INSTALLATION
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plateau pto30-ulpg1Plateau pto30-lpg1

Table of Contents