Regency Plateau PTO30-NG1 Owners & Installation Manual page 20

Hide thumbs Also See for Plateau PTO30-NG1:
Table of Contents

Advertisement

INSTALLATION
PTO30 BURNER MUST BE INSTALLED AT A MINIMUM OF 750MM ABOVE GROUND. IF INSTALLED LOWER, IT IS REQUIRED TO
INSTALL THE DECORATIVE GLASS SURROUND AND ENSURE MINIMUM HEIGHT IS 750MM TO TOP OF GLASS SURROUND.
IF INSTALLED LOWER THAN 750MM WITH GLASS SURROUND, INSTALLER MUST PROVIDE A MEANS OF SECONDARY GUARD,
NOT ATTACHED TO, BUT SURROUNDING THE PTO30 BURNER WITH A MINIMUM HEIGHT OF 750MM.
INSTALL ON 200MM (MINIMUM) MASONRY RISER OR SIMILAR; OR,
INSTALL ON 50MM (MINIMUM) MASONRY RISER OR SIMILAR WITH THE 'GLASS SURROUND.
Follow these instructions to construct a steel stud see through frame for the PTO30 burner;
Overall dimensions =64-1/16" (1627mm) W x 51"(1295mm) H x 19" (483mm)D .
**Non-combustible fi nishing board not supplied with kit. Board may be purchased at your local hardware/building supply store.
IMPORTANT: Supplied vents need to be installed into non-combustible fi nishing board, before applying fi nishing materials. Follow guidelines
included with these instructions.
1 power
drill
+ #2 phillips bit
1 hand
#2 screwdriver
(Phillips)
1 level
1
tape
measure
377-908 CONTENTS:
Top / Bottom
(A) x 2
Vertical Supports - Tall
(B) x 8
Vertical Supports - Short
(C) x 6
Base
(D) x 1
Short Brace
(E) x 4
Header
(F) x 2
Vents
4
Wafer Screws
80
NOTE: IF THE BURNER HAS BEEN
CONVERTED TO LPG, THE CYLINDER
CANNOT BE INSTALLED WITHIN
THE FRAMING KIT, AND MUST BE
CONNECTED VIA A PERMANENT
PIPING SYSTEM TO A REMOTE LPG
SUPPLY TANK
20
919-167a
ASSEMBLY INSTRUCTIONS FOR A STEEL STUD
ASSEMBLY INSTRUCTIONS FOR A STEEL STUD
SEE THROUGH FRAMING KIT FOR PTO30
SEE THROUGH FRAMING KIT FOR PTO30
Tools Required
1
PTO30
Regency Plateau™ PTO30 Outdoor Gas Fireplace
10/24/12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plateau pto30-ulpg1Plateau pto30-lpg1

Table of Contents