9) Remove 6 screws on valve access cover.
10) Remove Hi/Lo pressure regulator by removing 2 screws as shown below.
Reverse steps to install LP pressure regulator. (Be sure diaphragm and
spring are removed.)
11) Attach the label "This unit has been converted to LPG/ULPG" near or on
top of the serial # decal.
12) Replace yellow "NG" label with red "LPG/ULPG" label.
Make appropriate gas connections.
13) Check all gas connections under normal operating pressure, for leaks,
with soapy water.
NOTE: If soap bubbles, this would indicate a gas leak.
14) Check inlet and outlet pressures.
15) Check operation of fl ame control.