Gl Command System); Gl2 Command System); Rtl Command System) - Canon BJ-W3000 Service Manual

Hide thumbs Also See for BJ-W3000:
Table of Contents

Advertisement

15. 061xx (GL command system)
Code
W06100
• Unsupported command
W06111
• Incorrect number of
parameters
W06120
• Necessary parameters in
the command are omitted.
W06121
• Incorrect data range
16. 062xx (GL2 command system)
Code
W06200
• Unsupported command
W06211
• Incorrect number of
parameters
W06220
• Necessary parameters in
the command are omitted.
W06221
• Incorrect data range
17. 063xx (RTL command system)
Code
W06300
• Unsupported command
W06301
• Invalid data other than
null or FF (HEX) contin-
ued for more than 20
bytes.
W06311
• Incorrect number of
parameters
W06320
• Necessary parameters in
the command are omitted.
• Incorrect data range
W06321
Meaning
• While data is being
analyzed
Meaning
• While data is being
analyzed
Meaning
• While data is being
analyzed
CHAPTER 5. TROUBLESHOOTING
Detection timing
Detection timing
Detection timing
Major cause
• Incorrect data from computer
• Defective image controller
Major cause
• Improper communication data
from computer
• Defective image controller
Major cause
• Improper communication data
from computer
• Defective image controller