Air Purge - Samsung AP30M1 Series User & Installation Manual

Table of Contents

Advertisement

Air purge

❋ ❋ Be sure that all valve cocks are closed.
f The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the
f
compressor, reduce to cooling capacity and could lead to a malfunction. Use Vacuum Pump as shown at the figure.
1. Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut.
2. Connect the charging hose of low pressure side of manifold gauge to the packed valve having a service port as shown at
the figure.
3. Open the valve of the low pressure side of manifold gauge counter-clockwise.
4. Purge the air from the system using vacuum pump for about 10 minutes.
- Close the valve of the low pressure side of manifold gauge clockwise.
- Turn off the vacuum pump.
- Make sure that pressure gauge show -0.1MPa(-76cmHg) after about 10 minutes.
- This procedure is very important in order to avoid gas leak.
- Remove the hose of the low pressure side of manifold gauge.
5. Set valve cork of both liquid side and gas side of packed valve to the open position.
6. Mount the cap and the needle valve cap to the valve (see the below illustration), and tighten them at the torque of
183kgf•cm with a torque wrench.
7. Check for gas leakage.
- At this time, especially check for gas leakage from the 3-way valve's stem nuts, and from the service port cap.
Gas pipe
side
Liquid pipe
side
Mirage_AP30M0@_IBIM_E_34518A(1).indd 49
OUTDOOR UNIT
A
B
Flare nut
Valve cock
Cap
Needle valve
cap
Liquid pipe side
Vacuum Pump
3-way valve
Outdoor unit
Indoor unit
Gas pipe side
3-way valve
49
2012-02-01 오후 4:07:53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap30m0 series

Table of Contents