Troubleshooting
Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses.
PROBLEM
The air conditioner does not operate
immediately after it has been
restarted.
The air conditioner does not work
at all.
The temperature does not change.
The cool(warm) air does not come
out of the air conditioner.
The fan speed does not change.
Timer function does not set.
Odors permeate in the room during
operation.
The air conditioner makes a bubbling
sound.
Water is dripping from the air flow
blades.
Remote controller is not working.
Smoke is generated from the
outdoor unit.
Error is indicated.
30
Mirage_AP30M0@_IBIM_E_34518A(1).indd 30
• Because of the protective mechanism, the appliance does not start operating
immediately to keep the unit from overloading. The air conditioner will start in 3
minutes.
• Check if the circuit breaker is switched off.
• Check if there is a power failure.
• Check your fuse. Make sure it is not blown out.
• Check if you selected Fan mode. Press the Mode button on the remote controller to
select another mode.
• Check if the set temperature is higher (lower) than the current temperature. Press the
Temp + or - button on the remote controller to change the set temperature. Press the
Temp + or - button to increase or decrease the temperature.
• Check if the air filter is blocked by dirt. Clean the Air filter every two weeks.
• If the air conditioner has just been turned on or the indoor temperature reaches
the desired temperature, only fan will operate around 3 minutes for the product
protection. Also, just after you start the heating operation, warm air will come out after
for a while to avoid cold air from coming out.
• Check if you selected Auto or Dry mode. The air conditioner automatically adjusts the
fan speed to Auto in Auto/Dry mode.
• Check if you press the Set button on the remote controller after you have set the time.
• Check if the appliance is running in a smoky area or if there is a smell entering from
outside. Operate the air conditioner in Fan mode or open the windows to air out the
room.
• A bubbling sound may be heard when the refrigerant is circulating through the
compressor. Let the air conditioner operate in a selected mode.
• Check if the air conditioner has been cooling for an extended period of time with the
air flow blades pointed downwards. Condensation may generate due to the difference
in temperature.
• Check if your batteries are depleted.
• Make sure batteries are correctly installed.
• Make sure nothing is blocking your remote control sensor.
• Check that there are strong lighting apparatus near the air conditioner. Strong light
which comes from fluorescent bulbs or neon signs may interrupt the electric waves.
• It may not be a fire but it can be a steam generated by the defrost operation from
outdoor heat exchanger during Heat mode in winter.
• Contact the service center when the following errors are indicated.