Minimum Framing Dimensions - Rear Vent Configuration

Firestop
(required)
34.25" Minimum
Enclosure Height
WARNING: A cut-out for the gas line
may be required on the framing.
Make Sure the Fireplace is Raised a Minimum 3/8" (9mm)
!
Faces, when installed, extend 3/8" (9mm) below the base of the fireplace. Make sure the fireplace is
raised appropriately to allow for face installation.
Travis Industries
Installation
34.25"
12.375"
20.25"
(for qualified installers only)
Vent Clearances:
1" to the sides, 1" below, and 3" above
the vent to combustibles.
NOTE: The rear vent may require extra
clearance - make sure to accommodate the
vent when determining the framing.
4150309
Center of Rear Vent
27.25"
HINT: we recommend
reinforcing the upper corners of
the fireplace opening.
4"
2.75"
Route the electrical line to a position
to the right rear of the fireplace.
Thermostat or Remote
Control Wire (right side)
100-01421