Top Vent Configuration With Vertical Termination - Travis Industries 21 TRV GSR2 Installation Manual

Hide thumbs Also See for 21 TRV GSR2:
Table of Contents

Advertisement

Top Vent Configuration with Vertical Termination

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Up to four elbows (45° or 90°) may be used.
Only one horizontal elbow may be used.
May use 8" or 6-5/8" diameter vent (see page for 25 details).
Restrictor Position # 3
Diffuser Position # 1 (stock)
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
Travis Industries
Installation
40' (max)
35 feet
Restrictor Position # 2
30 feet
Diffuser Position # 1 (stock)
25 feet
NOTE:
Two 45° elbows
may be used.
20 feet
Restrictor Position # 1 (stock)
15 feet
Diffuser Position # 1 (stock)
10 feet
6' (min)
5 feet
0 feet
H1
(for qualified installers only)
40' (max)
NOTE:
Restrictor positions are
based upon lab tests.
The ideal restrictor
position may vary
slightly, especially when
35 feet
the termination is near a
demarkation line.
30 feet
25 feet
20 feet
15 feet
10 feet
6' (min)
5 feet
0 feet
H2
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
4150309
NOTE:
One 45° or 90° elbow may
be used between horizontal
sections. Horizontal length
is caculated by adding each
horizontal run together.
NOTE:
Horizontal sections require a
1/4" rise every 12" of travel.
29