Electrical Connection (required)
•
The electrical line to the grounded input wires inside the fireplace must be installed by a qualified
installer and must meet all local codes.
•
Make sure the household breaker is shut off prior to working on any electrical lines.
•
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.1.
•
The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)
Caution : Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
a
© Travis Industries
Installation
Remove the cover from the
fireplace junction box.
c
Remove the knock-out from the cover plate.
Secure the romex connector to the cover plate. Route
d
the electrical line through the cover plate and attach to
the three electrical leads. Replace the cover plate plate.
(for qualified installers only)
The three connection wires and a romex
b
clamp are inside the junction box.
NOTE: An alternative knock-out is
provided in the base of the
fireplace if you wish to run the
electrical line from below.
4080207
2 1