Required Electrical Connection

Make sure power to the heater has been turned off prior to installation (disable the breaker).
Do not connect 110-120 VAC to the gas control valve or the on/off circuit on this fireplace.
This fireplace utilizes 110 VAC to power the receiver module and intermittent pilot system. A
separate battery box is included to provide power in case of power outages (see "Battery Pack –
Learn Switch Installation" on page 18 for details).
The electrical line to the grounded receptacle inside the fireplace must be installed by a
qualified installer and must meet all local codes. The fireplace must be properly grounded in
accordance with local codes (or ANSI/NFPA 70-1987).
Make sure the household breaker is shut off prior to working on any electrical lines.
The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)
The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Attach an electrical line to the receptacle inside the control box (see the illustration below).
Make sure to connect the ground wire to the grounding tab on the receptacle (this grounds the
fireplace).
Attach the electrical line,
including the grounding wire,
to this receptacle.
© Travis Industries
Installation
(for qualified installers only)
Control Box
Cover Plate
Romex Connector
Grounded 110V
Power Supply
4100519
17