Maintenance & Troubleshooting
2. When re-installing the friction bearing onto the ADF pick-up assembly, ensure that the end of the
spring is inserted into the slot in the pick-up assembly, Figure 5.
7-7-11 Firmware Upgrade (WCP 412 Only)
Operational Groups:
All
Problem:
NONE: Informational Bulletin
Cause:
NONE: Informational Bulletin
Solution - Information
Introduction
The following information outlines the recent firmware that has been cut into the production line.
Firmware - Fixes included
It is possible to set a default time that allows the machine to reset the copy count back to default.
This can be found under SYSTEM SETUP and is listed as [TIMEOUT]
Image & shading quality have been improved.
The HELP report has been updated to account for changes to UI.
Image registration has been added to allow a Technician to modify the left and right margins of the
image on the page. This can only be modified in Tech mode. This is to be located in TECH mode
under MAINTENANCE a new entry has been added [ IMAGE REGI ]
Engine - Fixes included
Fuser, Transfer voltages and printing speed have been modified to take into account various paper
types.
Corrected the problem of printing blank pages when sending a print job.
7-46
Figure 5 Friction bearing