Maintenance & Troubleshooting
Cause:
User has set the machine up incorrectly and this has resulted in the fax failing to work properly.
Solution:
A service engineer will be required to perform the following steps.
1. Backup the customer phone book then enter TECH Mode
2. Press the MENU key
3. Locate the option MEMORY CLEAR and press the Select button.
4. Using the left and right cursor keys locate the desired country code.
5. Press Select to activate the choice. The machine will reset back to factory defaults.
6. Choose the correct language from the Maintenance menu and upload the phone book.
7-7-4 Drum Counter Reset After Changing Faulty Drum (WCP 412 Only)
Operational Groups:
OmniFax (USA), NASG-Canada, ESG
Problem:
If the customer has changed their drum for a new one, the printer has no way of resetting the drum counter
to zero. This will cause problems with the future page counters if the drum has not achieved a life of 14k
copies. This facility is required to prevent drum counter discrepancies at a later date.
Cause:
There is no facility on the machine or procedure in the firmware that allowed the user or engineer to reset
the drum counter.
Solution:
1. Confirm the presence of Firmware Level 1.01 or higher, if not present then upgrade the firmware on
the machine. This can be found on the www.xerox.com website.
2. Press the "Menu" button
3. Press either the "Up" or "Down" cursor arrows until the LCD screen shows Maintenance - [System....],
then press the "Select" button.
4. Press either the "Up" or "Down" cursor arrows until the LCD screen shows Maintenance - [New
Drum...], then press the "Select" button.
5. To clear the Drum counter Press "1" followed by "Select". To cancel press "2" followed by "Select".
Software Version:
Control Panel Management and Machine Control Firmware, v 1.01, dated September 25, 2001.
7-7-5 Toner Warning Message Does not Indicate Empty Toner Cartridge
Operational Groups:
Omnifax (USA), ESG, NASG-Canada
Problem:
The cartridge is empty, but the printer does not register an empty condition.
Cause:
It is possible that if the toner sensor windows in the printer become contaminated, the printer will fail to reg-
ister an empty cartridge.
7-40
3/03
WorkCentre Pro 412, FaxCentre F12 &
WorkCentre M15/M15i