Test Fail – Indicates the powered device test has failed. For example, a port could not
be enabled and cannot be used to deliver power to the powered device.
Testing – Indicates the powered device is being tested. For example, a powered device
is tested to confirm it is receiving power from the power supply.
Searching – Indicates the device is currently searching for a powered device.
Searching is the default PoE operational status.
Fault – Indicates the device has detected a fault on the powered device when the port
is forced on. For example, the power supply voltage is out of range, or there is a
communication error with PoE devices, or a short occurs or unknown error occurs.
Other Fault – Indicates the device has detected a fault on the powered device when the
port is not forced on. For example, a hardware fault occurred, or the system is
initializing, or the port is not responding, or there is an overload or underload, or the
power budget is exceeded or the maximum temperature is exceeded.
2. Click on the Unit No., located above the table, to display the PoE information of the unit's
ports. To display the PoE information for all interfaces of all the units, click All.
3. Select an interface.
4. Select the Admin Mode and Priority Level from the lists in the provided fields in the first
row.
5. Click APPLY to update the device.

SNMP

Simple Network Management Protocol (SNMP) provides a method for managing network
devices. The device supports the following SNMP versions:
SNMP v1 and v2c
SNMP version 3
The SNMP agents maintain a list of variables that are used to manage the device. The variables are
defined in the Management Information Base (MIB). The SNMP agent defines the MIB
specification format, as well as the format used to access the information over the network. Access
strings control access rights to the SNMP agents. SNMP v3 applies access control and a new traps
mechanism. In addition, User Security Model (USM) parameters are defined for SNMPv3,
including:
Authentication – Provides data integrity and data origin authentication.