12-9
FI SYSTEM DIAGNOSIS
• Disconnect the connector/coupler included in circuit (coupler
B) and measure resistance between terminal A and body
ground.
If continuity is indicated, the circuit is shorted to the ground
between terminals A and B.

USING THE MULTI-CIRCUIT TESTER

• Use the Suzuki multi-circuit tester set (09900-25008).
• Use well-charged batteries in the tester.
• Be sure to set the tester to the correct testing range.
USING THE TESTER
• Incorrectly connecting the + and - probes may cause the
inside of the tester to burnout.
• If the voltage and current are not known, make measure-
ments using the highest range.
• When measuring the resistance with the multi-circuit tester 1,
∞ will be shown as 10.00 MΩ and "1" flashes in the display.
• Check that no voltage is applied before making the measure-
ment. If voltage is applied the tester may be damaged.
• After using the tester, turn the power off.
! 09900-25008: Multi-circuit tester set
NOTE:
* When connecting the multi-circuit tester, use the needle
pointed probe to the back side of the lead wire coupler and
connect the probes of tester to them.
* Use the needle pointed probe to prevent the rubber of the
water proof coupler from damage.
* When using the multi-circuit tester, do not strongly touch the
terminal of the ECM coupler with a needle pointed tester probe
to prevent the terminal damage or terminal bend.
! 09900-25009: Needle pointed probe set