Post event
Time that an event has occurred
Record the post-conditions from the point that an
event has occurred.
5 seconds~5 Minutes: Set the recording time after
the event occurrence.
video size
Screen setup size displayed on record mode.
video
Full d1
source
NTSC
704 X 480
PAL
704 X 576
If the 1-channel DVR support is set to On in the
monitoring menu, the resolution is changed to
Full D1.
Alarm Detection Setup
alarm detection setup
alarm in
state
alarm in 1
n.o
alarm in 2
n.o
alarm in 3
n.o
alarm in 4
n.o
move/Control
state
The Alarm In type can be set to "n.o" or "n.c".
n.o (normally open): Sensor remains open. But if it
gets closed, an alarm is issued.
n.c (normally closed): Sensor remains closed. But
if it gets open, an alarm is issued.
32_ menu setup
SHR-5042_Eng_02.indd 32
Post-Event Section
half d1
ciF
704 X 240
352 X 240
704 X 288
352 X 288
Camera
alarm-out
duration
1
none
10 seC
2
none
10 seC
3
none
10 seC
4
none
10 seC
ok
Cancel
select
exit
camera
Sets the camera linked to the current Alarm In. The
default value is set to the current Alarm In number.
At least one link between Alarm In and camera has to
be established. Multiple selections are possible.
The following screen will appear if the enter(
button is pressed by moving the cursor from the
camera item.
Camera 1
Camera 2
Camera 3
Camera 4
all
ok
Cancel
Alarm out
Sets an alarm-out method when an event has
occurred from the Alarm In.
Currently, this system supports 2 Alarm Out functions
and 1 built-in speaker (beep) output.
The following screen will appear if the enter(
button is pressed by moving the cursor from the Alarm
Out item.
1
2
Beep
all
ok
Cancel
duration
Sets the duration for Alarm Out. The alarm sound will
be maintained with the value set.
continUe: The alarm output sound will be
maintained until it is cancelled by pressing the ALArM
button manually on the front panel.
10~300 seconds: You can set the duration for the
alarm output.
)
)
2008-01-25 오전 9:31:25