Fujitsu AG * V09LAC Series Service Instruction page 56

Split type room air conditioner
Table of Contents

Advertisement

JP (Jumper) Setting
[Indoor Unit]
AG*V09/ 12/ 14LAC
- Remote control custom code
When multiple number of indoor units are installed in the same room, erroneous receipt of the signal can
be avoided by setting up the remote control custom code separately.
To set up the remote control custom code, always set up the same code on both indoor unit PCB and
remote control PCB.
(When the indoor unit PCB is changed to Code B, it can not receive the signal unless remote control PCB
is also changed to Code B.)
Code A (Default)
Code B
- Auto Restart
It is possible to disengage Auto Restart function if it is not needed.
With Auto Restart function
(Default)
Without Auto Restart
function
[Outdoor Unit]
AO*V09/ 12/ 14LAC
Normal Preheat
09LAC
Higher Preheat
Normal Preheat
12LAC
Higher Preheat
Normal Preheat
14LAC
Higher Preheat
- it is possible to select the higher or standard level of preheating function.
- When it is set up at the higher level of preheat, the magnetic noise of the compressor becomes higher.
Indoor Unit
Remote Control
JM1 (JP)
Indoor Unit
JM2 (JP)
JP
JM500
JM103
JM102
08-01
J4 (JP)
JM101

Advertisement