Heating Operation - Fujitsu AG * V09LAC Series Service Instruction

Split type room air conditioner
Table of Contents

Advertisement

2. HEATING OPERATION

2-1 HEATING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is lower by 3°C than a set temperature, the compressor operation
frequency will attain to maximum performance.
* If the room temperature is higher 2.5°C than a set temperatire, the compressor will be
stopped.
* When the room temperature is between +2°C to -3°C of the setting temperature,
the compressor frequency is controlled within the range shown in Table2.
However, the maximum frequency is limited in the range shown in Figure 2 based on the
fan speed mode and the outdoor temperature.
( Table 2 : Compressor Frequency Range )
AG*V09LAC
AG*V12LAC
AG*V14LAC
( Fig.2 : Limit of Maximum Frequency based on Outdoor Temperature )
Outside air
temperature
19°C
14°C
7°C
* The room temperature is controlled 2°C higher than the setting temperature for 60 minutes
after starting the operation.
After 60 minutes, it is controlled based on the normal setting temperature.
minimum
air flow
frequency
Upper & Lower
18Hz
Upper
Upper & Lower
18Hz
Upper
Outside air
temperature
C zone
17°C
B zone
12°C
A zone
5°C
AA zone
maximum
frequency
130Hz
119Hz
AG*V09/ 12LAC
130Hz
AA zone
Upper&
A zone
130Hz
Lower
B zone
130Hz
air flow
130Hz
C zone
130Hz
AA zone
Upper
A zone
130Hz
air flow
B zone
130Hz
C zone
130Hz
AG*V14LAC
119Hz
AA zone
Upper&
A zone
119Hz
Lower
B zone
119Hz
air flow
C zone
119Hz
AA zone
119Hz
Upper
A zone
119Hz
air flow
B zone
119Hz
C zone
119Hz
05-02
Hi
Me
Lo
96Hz
57Hz
96Hz
64Hz
96Hz
80Hz
96Hz
80Hz
96Hz
48Hz
96Hz
64Hz
96Hz
80Hz
96Hz
80Hz
Hi
Me
Lo
90Hz
54Hz
90Hz
70Hz
90Hz
70Hz
90Hz
70Hz
90Hz
38Hz
90Hz
42Hz
90Hz
49Hz
90Hz
54Hz
Quiet
45Hz
51Hz
68Hz
68Hz
33Hz
45Hz
51Hz
68Hz
Quiet
30Hz
38Hz
45Hz
54Hz
30Hz
38Hz
38Hz
45Hz