Name
STB*
IBF
ACK*
OBF*
INTR
RD*
WR*
DATA
© National Instruments Corporation
Table 4-2. Signal Descriptions
Type
Input
Strobe input—A low signal on this handshaking line
loads data into the input latch.
Output
Input buffer full—A high signal on this handshaking
line indicates that data has been loaded into the input
latch. A low signal indicates the device is ready for
more data. This is an input acknowledge signal.
Input
Acknowledge input—A low signal on this
handshaking line indicates that the data written to the
port has been accepted. This signal is a response from
the external device indicating that it has received the
data from your DIO device.
Output
Output buffer full—A low signal on this handshaking
line indicates that data has been written to the port.
Output
Interrupt request—This signal becomes high when
the 82C55A requests service during a data transfer. You
must set the appropriate interrupt enable bits to
generate this signal.
Internal
Read—This signal is the read signal generated from
the control lines of the computer I/O expansion bus.
Internal
Write—This signal is the write signal generated from
the control lines of the computer I/O expansion bus.
Bidirectional
Data lines at the specified port—For output mode,
this signal indicates the availability of data on the data
line. For input mode, this signal indicates when the data
on the data lines should be valid.
Description