C534, C534i Self Powered Elliptical Fitness Crosstrainer
•
Diagram 7.1 - Display Housing Front Panel, Rear View
J5 Connector--
: l - - - -
Upper PCA
Keypad
- - Connector
Keypad
7.
Position the upper PCA at its mounting location on the display housing front panel (refer to
Diagram 7.1). Replace and tighten the upper PCA mounting screws.
8.
Reconnect the keyboard cable to the upper PCA.
9.
Reconnect the upper interconnect cable to the upper PCA.
10. Remove the ground lead of the wrist strap from the EFX frame, then remove the wrist strap
from your arm.
11. Position the display enclosure on the display plate. Replace and tighten the display
mounting screws.
12. Replace the red battery lead removed in step 1 and check unit operation as described in
Section Four.
•
Page 30