C534. C534i Self Powered Elliptical Fitness Crosstrainer
8.
If either the input pUlley belt or the generator belt is being replaced with a new belt, the belt
tension should be set 20 Ibs. higher than the previous readings. Therefore a new input
pulley belt should be tensioned to 120 Ibs. and a new generator belt should be tensioned to
80 Ibs. Over time and use the belts will "relax" and the tensions will be as stated in steps 4
and 7.
9.
Reconnect the red battery lead to terminal M6 of the lower peA.