Installation Procedure - Toshiba RAS-18, 22SKV-E Service Manual

Hide thumbs Also See for RAS-18, 22SKV-E:
Table of Contents

Advertisement

10-1. Installation Diagram of Indoor and Outdoor Units
Pure Air Purifier
SKVR only
5 Filter
3 Batteries
Vinyl tape
Apply after carrying
out a drainage test.
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
2 Wireless remote controller

10. INSTALLATION PROCEDURE

2 Wireless remote controller
6 Filter
8
Pan head
wood screw
Extension drain hose
(Not available, provided by installer)
Hook
1 Installation
plate
Shield pipe
4 Remote controller
holder
Saddle
3 Batteries
– 56 –
FILE NO. SVM-10050
For the rear left and left piping
Wall
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Do not allow the drain hose to get slack.
Cut the
piping hole
sloped slightly.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be connected
to the left, rear left, rear right, right,
bottom right or bottom left.
Right
Rear right
Rear
left
Bottom right
Bottom left
Insulate the refrigerant pipes separately
with insulation, not together.
8 mm thick heat resisting
polyethylene foam
Left