6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
Parts name
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
No.
Parts name
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (5P)
8
Compressor
9
Coil for PMV
10
Coil for 4-way valve
18SAV-E2, 18SAV2-E,
18SAV2-A
22SAV-E2, 22SAV2-E,
22SAV2-A
Type
ICF-340-30-2Β
DC340V, 30W
( — )
10kΩ at 25°C
( — )
10kΩ at 25°C
MP24Z3T
Output (Rated) 1W, 16 poles, DC12V
Model name
CH-57
L = 10mH, 16A
ICF-140-43-4R
DC140V, 43W
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
62kΩ (20°C)
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
10kΩ (25°C)
——
20A, AC250V
DA130A1F-27F
3-phases 4-poles 1100W
DA150A1F-20F
CAM-MD12TCTH-2
DC12V
AC220–240V
STF
– 24 –
FILE NO. SVM-10050
Specifications
Rating

Hide quick links: