Toshiba RAS-18, 22SKV-E Service Manual page 6

Hide thumbs Also See for RAS-18, 22SKV-E:
Table of Contents

Advertisement

RAS-18SKVR-E / RAS-18SAV-E2
RAS-22SKVR-E / RAS-22SAV-E2
Indoor
Unit model
Outdoor
Cooling capacity
Cooling capacity range
Heating capacity
Heating capacity range
Power supply
Indoor
Electric
characteristic
Outdoor
COP
Indoor
Sound pressure
level
Outdoor
Indoor
Sound power
level
Outdoor
Unit model
Dimension
Indoor unit
Net weight
Fan motor output
Air flow rate
Unit model
Dimension
Net weight
Outdoor unit
Compressor
Fan motor output
Air flow rate
Type
Indoor unit
Piping
Outdoor unit
connection
Maximum length
Maximum chargeless length
Maximum height difference
Name of refrigerant
Refrigerant
Weight
Wiring connection
Usable temperature range
Indoor unit
Accessory
Outdoor unit
• The specifications may be subject to change without notice for purpose of improvement.
Operation mode
Running current
Power consumption
Power factor
Operation mode
Running current
Power consumption
Power factor
Starting current
H / M+ / M / L+ / L
H
H / M+ / M / L+ / L
H
Height
Width
Depth
(Cooling/Heating)
Height
Width
Depth
Motor output
Type
Model
(Cooling/Heating)
Liquid side
Gas side
Liquid side
Gas side
Power supply
Interconnection
Indoor (Cooling/Heating)
Outdoor (Cooling/Heating)
Installation plate
Wireless remote controller
Batteries
Remote controller holder
Toshiba New IAQ filter
Mounting screw
Remote controller holder
Pan head wood screw
Plasma air purifier
Installation manual
Owner's manual
Drain nipple
Water-proof rubber cap
RAS-18SKVR-E
RAS-18SAV-E2
(kW)
5.0
(kW)
1.1 – 6.0
(kW)
5.8
(kW)
0.8 – 6.3
1 Ph / 50Hz / 220 – 240V, 1 Ph / 60Hz / 220 – 230V
Cooling
(A)
0.30 – 0.28
0.30 – 0.28
(W)
40
(%)
60
Cooling
(A)
6.40 – 5.87
6.98 – 6.40
(W)
1380
(%)
98
(A)
7.28-6.68
3.52
(dB-A)
44/41/38/35/32 44/41/39/35/32 47/44/41/38/35 47/44/42/38/35
(dB-A)
49
(dB-A)
59/56/53/50/47 59/56/54/50/47 62/59/56/53/50 62/59/57/53/50
(dB-A)
64
RAS-18SKVR-E
(mm)
320
(mm)
1050
(mm)
228
(kg)
13
(W)
30
(m³/min)
15.9 / 16.5
RAS-18SAV-E2
(mm)
550
(mm)
780
(mm)
290
(kg)
41
(W)
1100
Twin rotary type with DC-inverter variable speed control
DA130A1F-27F
(W)
43
(m³/min)
36.3 / 31.9
Flare connection
(mm)
Ø6.35
(mm)
Ø12.70
(mm)
Ø6.35
(mm)
Ø12.70
(m)
20
(m)
15
(m)
10
R410A
(kg)
1.40
3 Wires: includes earth (Outdoor)
(°C)
21 ~ 32 / ~ 28
(°C)
–10 ~ 46 / –15 ~ 24
1
1
2
1
2
6 (Ø4 × 25L)
2 (Ø3.1L × 16L)
1
1
1
1
2
– 6 –
FILE NO. SVM-10050
RAS-22SKVR-E
RAS-22SAV-E2
6.0
1.2 – 6.7
7.0
1.0 – 7.5
Heating
Cooling
0.38 – 0.35
40
50
60
60
Heating
Cooling
8.93 – 8.19
1520
1945
99
99
9.56-8.77
3.72
3.01
50
53
65
68
RAS-22SKVR-E
320
1050
228
13
30
17.7 / 18.0
RAS-22SAV-E2
550
780
290
41
1100
DA150A1F-20F
43
38.6 / 37.2
Flare connection
Ø6.35
Ø12.70
Ø6.35
Ø12.70
20
15
10
R410A
1.40
4 Wires: includes earth
21 ~ 32 / ~ 28
–10 ~ 46 /–15 ~ 24
1
1
2
1
2
6 (Ø4 × 25L)
2 (Ø3.1L × 16L)
1
1
1
1
2
Heating
0.38 – 0.35
50
60
Heating
9.18 – 8.42
2000
99
3.41
52
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents