Toshiba RAS-18 Installation Manual
Hide thumbs Also See for RAS-18:

Advertisement

INSTALLATION MANUAL

AIR CONDITIONER (SPLIT TYPE)

Indoor unit

RAS-18, 22SKV(R) Series
Cover 1110651154.indd 1
Cover 1110651154.indd 1

Outdoor unit

RAS-18, 22SAV Series
1110651154
1/22/10 11:14:26 AM
1/22/10 11:14:26 AM

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAS-18

  • Page 1: Installation Manual

    INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) Indoor unit Outdoor unit RAS-18, 22SKV(R) Series RAS-18, 22SAV Series 1110651154 Cover 1110651154.indd 1 Cover 1110651154.indd 1 1/22/10 11:14:26 AM 1/22/10 11:14:26 AM...
  • Page 2: Table Of Contents

    CONTENTS PRECAUTIONS FOR SAFETY ........1 OUTDOOR UNIT ............6 Installation Place ............. 6 INSTALLATION DIAGRAM OF INDOOR AND Precautions about Installation in Regions with OUTDOOR UNITS ............3 Snowfall and Cold Temperatures ......6 Optional Installation Parts ........3 Refrigerant Piping Connection .........
  • Page 3: Precautions For Safety

    PRECAUTIONS FOR SAFETY PRECAUTIONS FOR SAFETY • Before installation, please read these precautions for safety carefully. • Be sure to follow the precautions provided here to avoid safety risks. The symbols and their meanings are shown below. WARNING : It indicates that incorrect use of this unit may cause severe injury or death. CAUTION : It indicates that incorrect use of this unit may cause personal injury (*1), or property damage (*2).
  • Page 4 CAUTION • Exposure of unit to water or other moisture before installation could result in electric shock. Do not store it in a wet basement or expose to rain or water. • After unpacking the unit, examine it carefully for possible damage. •...
  • Page 5: Installation Diagram Of Indoor And Outdoor Units

    INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS Pure Air Purifi er SKVR only For the rear left and left piping Installation Hook plate Wall Insert the cushion between the indoor unit and wall, and tilt the indoor unit for better operation.
  • Page 6: Indoor Unit

    INDOOR UNIT INDOOR UNIT When the installation plate is directly mounted Installation Place on the wall • A place which provides the spaces around the indoor unit as shown in the 1. Securely fi t the installation plate onto the wall by screwing it in the upper diagram and lower parts to hook up the indoor unit.
  • Page 7: Wiring Connection

    1. Die-cutting front panel slit Wiring Connection Cut out the slit on the leftward or right side of the front panel for the left or right connection and the slit on the bottom left or right side of the front panel for the bottom left or right connection with a pair of nippers.
  • Page 8: Indoor Unit Fixing

    NOTE Information If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. The lower part of indoor unit may fl oat, After passing the connecting pipe through the pipe hole, connect the due to the condition of piping and you connecting pipes to the auxiliary pipes and wrap the facing tape around cannot fi...
  • Page 9: Refrigerant Piping Connection

    1. Connect the charge hose from the manifold valve to the service port of Refrigerant Piping Connection the packed valve at gas side. 2. Connect the charge hose to the port of the vacuum pump. 3. Open fully the low pressure side handle of the gauge manifold valve. Flaring 4.
  • Page 10: Others

    Stripping length of the connecting cable CAUTION • Wrong wiring connection may cause some electrical parts burn out. 1 2 3 • Be sure to comply with local rule on running the wire from indoor unit Terminal to outdoor unit (size of wire and wiring method, etc.). block •...